Connect at 8 data bits, 1 stop bit, and whichever baud/parity the unit is actually on — 115200, None for a factory-fresh unit (the manual's own default), or 19200, Even for one that's already been provisioned (confirmed on the units configured so far for this client; a different client's units may end up on a different value after their own provisioning). Pick it in the connection card before clicking Connect. The gateway prints its own continuous boot/status chatter from the moment the port opens, mixed characters with no reliable line breaks — that's normal and happens regardless of anything sent to it. Once baud/parity match the unit, the manual's original handshake shape turns out to be correct after all:
- First, send a bare
AT and check for a reply ("OK" or any "+CME ERROR") — those only happen in AT mode, so seeing one means the gateway is already there (e.g. an earlier session left it in AT mode and it never left). If so, skip straight to AT mode — no +++ needed.
- Otherwise, wait a moment after the connection opens — not an instant
+++. The chatter continuing in the background is fine.
- Send
+++ once.
- Watch for
a to show up, mixed in with more chatter — confirmed to arrive well under a second later.
- Within that same second or so, send
a back once.
+ok follows shortly after, mixed into the stream the same way — that's AT command mode.
This app does exactly that automatically on Connect, watching the raw byte stream rather than waiting for a clean line. It sends AT (the already-in-AT-mode check), then +++ and a once each if needed — no spamming — and if a step times out it stops and reports it rather than retrying on its own; click "Enter AT mode" to try again by hand. If you ever see "+CME ERROR:58" right after "+++" instead of "a", that's this exact already-in-AT-mode case, not a wrong baud/parity. To leave AT mode and resume normal MQTT/transparent operation, send AT+ENTM (confirmed in the manual). Disconnecting does this for you.